HiRISE

HiRISE.HiPlan.HiTemp
Class HiTemp_Batch

java.lang.Object
  extended by HiRISE.HiPlan.HiTemp.HiTemp_Batch

public class HiTemp_Batch
extends Object

A non-GUI batch-mode HiTemp application.

Version:
1.16
Author:
Christian Schaller - UA/PIRL

Field Summary
static double DEFAULT_MODEL_DURATION
          The default model duration for the batch-mode HiTemp.
static int FAILURE
          Exit status for an unsuccessful operation.
static String ID
          Class identification name with source code version and date.
static int SUCCESS
          Exit status for a successful operation.
 
Method Summary
static void main(String[] args)
          Invokes an instance of the HiTemp batch-mode application.
 
Methods inherited from class java.lang.Object
clone, equals, finalize, getClass, hashCode, notify, notifyAll, toString, wait, wait, wait
 

Field Detail

ID

public static final String ID
Class identification name with source code version and date.

See Also:
Constant Field Values

DEFAULT_MODEL_DURATION

public static final double DEFAULT_MODEL_DURATION
The default model duration for the batch-mode HiTemp. A value of less than 0.0 for model duration indicates the application will pick the duration automatically, setting it for six hours after the last observation.

See Also:
Constant Field Values

SUCCESS

public static final int SUCCESS
Exit status for a successful operation.

See Also:
Constant Field Values

FAILURE

public static final int FAILURE
Exit status for an unsuccessful operation.

See Also:
Constant Field Values
Method Detail

main

public static void main(String[] args)
Invokes an instance of the HiTemp batch-mode application. At least one input source of observation IDs must be supplied; see Observation_ID_Accumulator for information about sources.

Usage

HiTemp_Batch [--configuration configuration_pathname] [--duration auto|Nw|Nd|Nh|Nm|Ns] [--fpa-temp fpa_temp] [--fpea-temp fpea_temp] [--iea-temp iea_temp] [--timeline output_timeline_filename] [--output outputFilename] observation_id_source [...]

HiTemp_Batch --usage

HiTemp_Batch --version

Options are not case-sensitive and may be reduced to their shortest unique form. One or two dashes may be used.

Options

--configuration configuration_pathname
Sets the pathname of the configuration file from which to configure the application. See Configuration_Helper.getConfiguration(String,String,String...) for details on the configuration pathname; if this option is not used, the config source argument is null.
--duration auto|Nw|Nd|Nh|Nm|Ns
Sets the model run's duration. If auto, the application determines the run length from the input source timeline. Otherwise it is N weeks, days, hours, minutes, or seconds. The default is auto.
--fpa-temp fpa_temp
Sets the model's initial FPA temperature. if not specified, the value is taken from the application's configuration; if not included in the configuration, Thermal_Model.DEFAULT_FPA_SET_POINT_TEMPERATURE is used.
--fpea-temp fpea_temp
Sets the model's initial FPEA temperature. if not specified, the value is taken from the application's configuration; if not included in the configuration, Thermal_Model.DEFAULT_FPEA_SET_POINT_TEMPERATURE is used.
--iea-temp iea_temp
Sets the model's IEA temperature. If not specified, the value is taken from the application's configuration; if not included in the configuration, Thermal_Model.DEFAULT_IEA_TEMPERATURE is used.
--timeline output_timeline_filename
Sets the output timeline filename. If not specified, the timeline is not written to output.
--output outputFilename
Sets the output temperature profile filename. If not specified, the temperature profile will be written to the standard output stream.

Parameters:
args - the command-line arguments.

HiRISE

Copyright (C) Arizona Board of Regents on behalf of the Planetary Image Research Laboratory, Lunar and Planetary Laboratory at the University of Arizona